Commercial Water Filters
Water Filters
Series EWS 2” L Simplex Commercial Activated Carbon Backwash Filter
FEATURES:
2” NPT inlet and outlet top mounted lead free brass epoxy coated control valve.
Electronic flow meter with accuracy within plus or minus 5 percent, flow rate range 1.5 to 75 gpm. Gallons range 500 to 250,000 gallons 1 to 9,999,000 totalizer.
Service flow rate up to 75 gpm, peak flow rate up to 88gpm, backwash flow rates up to 50 gpm.
Fully adjustable 6 cycle controls backwash, slow/fast rinse and service. 2 additional cycles for backwash or rinse.
Cycles of operation. Cycle One backwash 1-20 minutes or off, Cycle Two slow rinse 1 -99 minutes or off, Cycle Three second backwash 1 - 20 minutes or off, Cycle Four fast rinse 1 - 20 minutes or off, Cycle Five service.
Four methods to initiate regeneration, meter immediate, meter delayed, time clock delayed or pressure differential. 1 1/2 ” water distribution system utilizing single point distributor or hub and laterals for maximum flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F - 110°F (5°C - 44°C).
Solid state microprocessor c/w display for time of day, days until next regeneration, volume remaining, current flow rate and total volume used (totalizer).
Double backwash for optimum regeneration cleaning ability.
12 volt output AC transformer. 12 or 24 hour time clock.
1 – 28 days override on control valve programming.
Series
EWS 2” L Simplex Commercial Activated Coconut Shell Filter
FEATURES:
2” NPT inlet and outlet top mounted lead free brass epoxy coated control
valve.
Electronic flow meter with accuracy within plus or minus 5 percent,
flow rate range 1.5 to 75 gpm. Gallons range 500 to 250,000 gallons
1 to 9,999,000 totalizer.
Service flow rate up to 75 gpm, peak flow rate up to 88 gpm, backwash
flow rates up to 50 gpm.
Fully adjustable 6 cycle controls backwash, slow/fast rinse and service.
2 additional cycles for backwash or rinse.
Cycles of operation. Cycle One backwash 1-20 minutes or off, Cycle Two
slow rinse 1-99 minutes or off, Cycle Three second backwash 1-20 minutes
or off, Cycle Four fast rinse 1-20 minutes or off, Cycle Five service.
Four methods to initiate regeneration, meter immediate, meter delayed,
time clock delayed or pressure differential.
1 1/2” water
distribution system utilizing single point distributor or hub and laterals
for maximum flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F
- 110°F (5°C - 44°C).
Solid state microprocessor c/w display for time of day, days until next
regeneration, volume remaining, current flow rate and total volume used
(totalizer).
Double backwash for optimum regeneration cleaning ability.
12 volt output AC transformer. 12 or 24 hour time clock.
1 – 28 days override on control valve programming.
Series
EWS 2” L Simplex Commercial Activated Centaur Carbon Filter
FEATURES:
2” NPT inlet and outlet top mounted lead free brass epoxy coated control
valve.
Electronic flow meter with accuracy within plus or minus 5 percent,
flow rate range 1.5 to 75 gpm. Gallons range 500 to 250,000 gallons
1 to 9,999,000 totalizer.
Service flow rate up to 75 gpm, peak flow rate up to 88 gpm, backwash
flow rates up to 50 gpm.
Fully adjustable 6 cycle controls backwash, slow/fast rinse and service.
2 additional cycles for backwash or rinse.
Cycles of operation. Cycle One backwash 1-20 minutes or off, Cycle Two
slow rinse 1-99 minutes or off, Cycle Three second backwash 1-20 minutes
or off, Cycle Four fast rinse 1-20 minutes or off, Cycle Five service.
Four methods to initiate regeneration, meter immediate, meter delayed,
time clock delayed or pressure differential.
1 1/2” water
distribution system utilizing single point distributor or hub and laterals
for maximum flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F
- 110°F (5°C - 44°C).
Solid state microprocessor c/w display for time of day, days until next
regeneration, volume remaining, current flow rate and total volume used
(totalizer).
Double backwash for optimum regeneration cleaning ability.
12 volt output AC transformer. 12 or 24 hour time clock.
1 – 28 days override on control valve programming.
Please Contact Us to purchase any of these items or for a quote on any specialized commercial application.

80 Government Road