Commercial Water Softeners
Water Softeners

Series
EWS 1” Simplex Commercial Softener
FEATURES:
1” NPT inlet and outlet top mounted composite electronic control valve.
Electronic flow meter with accuracy within plus or minus 5 percent,
flow rate range 0.25 to 27 gpm. Gallons range 20 to 50,000 gallons,
1000 to 9,999,000, totalizer.
Service flow rate up to 27 gpm, peak flow rate up to 32 gpm, backwash
flow rates up to 27 gpm.
Fully adjustable 6 cycle controls backwash, slow/fast rinse, draw, refill
and service.
Parallel flow, alternating on demand soft water.
Cycles of operation. Cycle One backwash 6-12 minutes, Cycle Two draw/slow
rinse 45-75 minutes, Cycle Three second backwash 3-12 minutes, Cycle
Four fast rinse 3-8 minutes, Cycle Five regenerant refill (in service
with treated water), Cycle Six service.
Four methods to initiate regeneration, meter immediate, meter delayed,
time clock delayed or pressure differential.
1” water distribution system utilizing single point distributor or hub
and laterals for maximum flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F
- 110°F (5°C - 44°C).
Solid state microprocessor c/w display for time of day, days until next
regeneration, volume remaining, current flow rate and total volume used
(totalizer).
Double backwash for optimum regeneration cleaning ability and salt efficiency.
12 volt output AC transformer.
1 – 28 day override on control valve programming.
Brine tank salt grid for easy cleaning.
Brine tanks 18” x 33” or 24" x 50" c./w brine well and safety
float to eliminate overflowing tanks.
The brine tank has 500lb or 800lb water softening salt capacity.
1” FPT drain line, 1⁄/2” FPT brine line.
Series
EWS 1.5” Simplex Commercial Softener
FEATURES:
1 1/2” NPT inlet and outlet top mounted lead free brass epoxy coated
control valve.
Electronic flow meter with accuracy within plus or minus 5 percent,
flow rate range 0.5 to 60 gpm. Gallons range 500 to 250,000 gallons,
1 to 9,999,000 gallons totalizer.
Service flow rate up to 60gpm, peak flow rate up to 68 gpm, backwash
flow rates up to 50 gpm.
Fully adjustable 6 cycle controls backwash, slow/fast rinse, draw, refill
and service.
Soft water on demand soft water.
Cycles of operation. Cycle One backwash 1-20 minutes or off, Cycle Two
draw/slow rinse 1-99 minutes or off, Cycle Three second backwash 1-20
minutes or off, Cycle Four fast rinse 1-20 minutes or off, Cycle Five
regenerant refill (in service with treated water), Cycle Six service.
Four methods to initiate regeneration, meter immediate, meter delayed,
time clock delayed or pressure differential.
1 1/2 ” water distribution system utilizing single point distributor
or hub and laterals for maximum flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F
- 110°F (5°C - 44°C).
Solid state microprocessor c/w display for time of day, days until next
regeneration, volume remaining, current flow rate and total volume used
(totalizer).
Double backwash for optimum regeneration cleaning ability and salt efficiency.
12 volt output AC transformer.
1 – 28 day override on control valve programming.
Brine tank salt grid for easy cleaning.
Brine tanks 24” x 50” or 30" x 50" c./w brine well and safety
float to eliminate overflowing tanks.
The brine tank has 800lb or 1000lb water softening salt capacity.
1 1/4” FPT drain line, 3/4” FPT brine line.
Series
EWS 2” Simplex Commercial Softener
FEATURES:
2” NPT inlet and outlet top mounted lead free brass epoxy coated control
valve.
Electronic flow meter with accuracy within plus or minus 5 percent,
flow rate range 1.5 to 75 gpm. Gallons range 500 to 250,000 gallons,
1 to 9,999,000 gallons totalizer.
Service flow rate up to 75 gpm, peak flow rate up to 88 gpm, backwash
flow rates up to 50 gpm.
Fully adjustable 6 cycle controls backwash, slow/fast rinse, draw, refill
and service.
Soft water on demand.
Cycles of operation. Cycle One backwash 1-20 minutes or off, Cycle Two
draw/slow rinse 1-99 minutes or off, Cycle Three second backwash 1-20
minutes or off, Cycle Four fast rinse 1-20 minutes or off, Cycle Five
regenerant refill (in service with treated water) 0.1-99 minutes of
off, Cycle Six service.
Four methods to initiate regeneration, meter immediate, meter delayed,
time clock delayed or pressure differential.
1 1/2” water distribution system utilizing single point distributor
or hub and laterals for maximum flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F
- 110°F (5°C - 44°C).
Solid state microprocessor c/w display for time of day, days until next
regeneration, volume remaining, current flow rate and total volume used
(totalizer).
Double backwash for optimum regeneration cleaning ability and salt efficiency.
12 volt output AC transformer.
1 – 28 day override on control valve programming.
Brine tank salt grid for easy cleaning.
Brine tanks 24” x 50” or 30" x 50" c./w brine well and safety
float to eliminate overflowing tanks.
The brine tank has 800lb or 1000lb water softening salt capacity.
1 1/4” FPT drain line, 3/4” FPT brine line.
Series
EWS 2” H Duplex Commercial Softener
FEATURES:
2” NPT inlet and outlet/ 2 1/2" Victaulic lead free brass epoxy
coated control valve.
Electronic flow meters for each control valve with accuracy within plus
or minus 5 percent, flow rate range 1.5 to 125 gpm. Gallons range 10
to 999,000 gallons, 1000 to 999,999,000, totalizer.
Service flow rate up to 125 gpm, peak flow rate up to 150 gpm, backwash
flow rates up to 125 gpm.
Fully programmable and adjustable 9 cycle control valve that controls
backwash, slow/fast rinse, draw, refill 2nd backwash and service, up
to 9 cycles.
Progressive flow, parallel flow, alternating on demand soft water.
System designs
up to 4 vessels.
Cycles of operation. Cycle One backwash 1-95 minutes or off, Cycle Two
brine draw 1-180 minutes or off, Cycle Three slow rinse 1-95 minutes
or off, Cycle Four fast rinse 1-95 minutes or off, Cycle Five refill
0.1 - 99 minutes or off, Cycle Six hold (service) 1-480 minutes
or off, three additional cycles for second backwash, slow rinse, fast
rinse.
Four methods to initiate regeneration, meter immediate, meter delayed,
time clock delayed or pressure differential.
2” water distribution system utilizing hub and laterals for maximum
flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F
- 110°F (5°C - 44°C).
Solid state microprocessor c/w removable front panel, digital display
for time of day, days until next regeneration, volume remaining, current
flow rate and total volume used (totalizer). All 9 cycles are adjustable
in second level diagnostics and desired flow rates in each cycle.
Double backwash for optimum regeneration cleaning ability and salt efficiency.
24volt output AC transformer, 12 or 24 day clock.
1 – 28 day override on control valve programming.
Brine tank salt grid for easy cleaning.
Brine tanks 30” x 50” or 50" x 60" c./w brine well and safety
float to eliminate overflowing tanks.
The brine tank has 1000lb or 4500lb salt capacity.
Optional 2" inlet and outlet motorized bypass valve.

Series
EWS 3” Duplex Commercial Softener
FEATURES:
3” electronic microprocessor brass top mount control valve single or
multi unit systems with interlocking control valves.
Solid state electronic control processor c/w current flow rate, peak
flow rate, totalizer, hours between last two regenerations, hours since
last regeneration, volume remaining, remote start, time of day, cycle
step times and flow meter size and remote lockout variable reserve.
Fully adjustable 5 cycle control valve with backwash, brining, slow
rinse, rapid rinse and service.
Service flow rate up to 250 USGPM, peak flow rate up to 325 USGPM, backwash
flow rate up to 100 USGPM.
Operating pressure 20-125 psi, operating temperature 34°F - 110°F.
Nema 3R water resistant enclosure, no hard water bypass. Meter
accuracy plus or minus 5%. Salt grind for easy cleaning.
Safety float to eliminate
overflowing tanks.
Drain line 2" NPT, Brine Line 1" NPT, 3" Hub and Laterals.
Series
EWS 1” Duplex Commercial Softener
FEATURES:
1” NPT inlet and outlet top mounted composite electronic control valve.
Electronic flow meter with accuracy within plus or minus 5 percent,
flow rate range 0.25 to 27 gpm. Gallons range 20 to 50,000 gallons,
1000 to 9,999,000, totalizer.
Service flow rate up to 27 gpm, peak flow rate up to 32 gpm, backwash
flow rates up to 27 gpm.
Fully adjustable 6 cycle controls backwash, slow/fast rinse, draw, refill
and service.
Parallel flow, alternating on demand soft water.
Cycles of operation. Cycle One backwash 6-12 minutes, Cycle Two draw/slow
rinse 45-75 minutes, Cycle Three second backwash 3-12 minutes, Cycle
Four fast rinse 3-8 minutes, Cycle Five regenerant refill (in service
with treated water), Cycle Six service.
Four methods to initiate regeneration, meter immediate, meter delayed,
time clock delayed or pressure differential.
1” water distribution system utilizing single point distributor or hub
and laterals for maximum flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F
- 110°F (5°C - 44°C).
Solid state microprocessor c/w display for time of day, days until next
regeneration, volume remaining, current flow rate and total volume used
(totalizer).
Double backwash for optimum regeneration cleaning ability and salt efficiency.
12 volt output AC transformer.
Duplex alternating motorized
electronic control valve (1")
1 – 28 day override on control valve programming.
Brine tank salt grid for easy cleaning.
Brine tanks 18” x 33” or 24" x 50" c./w brine well and safety
float to eliminate overflowing tanks.
The brine tank has 500lb or 800lb water softening salt capacity.
1” FPT drain line, 1/⁄2” FPT brine line.
Series
EWS 1.5” Duplex Commercial Softener
FEATURES:
1 1/2” NPT inlet and outlet top mounted lead free brass epoxy coated
control valve.
Electronic flow meters with accuracy within plus or minus 5 percent,
flow rate range 0.5 to 60 gpm. Gallons range 500 to 250,000 gallons,
1 to 9,999,000, totalizer.
Service flow rate up to 60gpm, peak flow rate up to 68gpm, backwash
flow rates up to 50 gpm.
Fully adjustable 6 cycle controls backwash, slow/fast rinse, draw, refill
and service.
Parallel flow, alternating on demand soft water.
Cycles of operation. Cycle One backwash 1-20 minutes or off, Cycle Two
draw/slow rinse 1-99 minutes or off, Cycle Three second backwash 1-20
minutes or off, Cycle Four fast rinse 1-20 minutes or off, Cycle Five
regenerant refill (in service with treated water) 0.1 - 99 minutes or
off, Cycle Six service.
Four methods to initiate regeneration, meter immediate, meter delayed,
time clock delayed or pressure differential.
1 1/2” water distribution system utilizing single point distributor
or hub and laterals for maximum flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F
- 110°F (5°C - 44°C).
Solid state microprocessor c/w display for time of day, days until next
regeneration, volume remaining, current flow rate and total volume used
(totalizer). All 9 cycles are adjustable in second level diagnostics
and desired flow rates in each cycle.
Double backwash for optimum regeneration cleaning ability and salt efficiency.
12 volt output AC transformer.
Duplex alternating motorized electronic control valve programming.
1 – 28 day override on control
valve programming.
Brine tank salt grid for easy cleaning.
Brine tanks 24” x 50” or 30" x 50" c./w brine well and safety
float to eliminate overflowing tanks.
The brine tank has 800lb or 1000lb salt capacity.
1 1/4" FPT drain line, 3/4" FPT brine line.
Series
EWS 2.0” L Duplex Commercial Softener
FEATURES:
2” NPT inlet and outlet top mounted lead free brass epoxy coated control
valve.
Electronic flow meter with accuracy within plus or minus 5 percent,
flow rate range 1.5 to 75 gpm. Gallons range 500 to 250,000 gallons,
1 to 9,999,000 gallons totalizer.
Service flow rate up to 75gpm, peak flow rate up to 88gpm, backwash
flow rates up to 50 gpm.
Fully adjustable 6 cycle controls backwash, slow/fast rinse, draw, refill
and service.
Parallel flow, alternating on demand soft water.
Cycles of operation. Cycle One backwash 1-20 minutes or off, Cycle Two
draw/slow rinse 1-99 minutes or off, Cycle Three second backwash 1-20
minutes or off, Cycle Four fast rinse 1-20 minutes or off, Cycle Five
regenerant refill (in service with treated water)0.1-99 minutes or off,
Cycle Six service.
Four methods to initiate regeneration, meter immediate, meter delayed,
time clock delayed or pressure differential.
1 1/2” water distribution system utilizing single point distributor
or hub and laterals for maximum flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F
- 110°F (5°C - 44°C).
Solid state microprocessor c/w display for time of day, days until next
regeneration, volume remaining, current flow rate and total volume used
(totalizer).
Double backwash for optimum regeneration cleaning ability and salt efficiency.
12 volt output AC transformer.
Duplex alternating
motorized electronic control valve (2")
1 – 28 day override on control valve programming.
Brine tank salt grid for easy cleaning.
Brine tanks 24” x 50” or 30" x 50" c/w brine well and safety
float to eliminate overflowing tanks.
The brine tank has 800lb or1000lb water softening salt capacity.
1 1/4” FPT drain line, 3/4” FPT brine line.

Series
EWS 2” H Triplex Commercial Softener
FEATURES:
2” NPT inlet or outlet/ 2 1/2" Victaulic lead free brass epoxy
coated control valve.
Electronic flow meter with accuracy within plus or minus 5 percent,
flow rate range 1.5 to 125 gpm. Gallons range 10 to 999,000 gallons,
1000 to 999,999,000, totalizer.
Service flow rate up to 125gpm, peak flow rate up to 150 gpm, backwash
flow rates up to 125 gpm.
Fully programmable and adjustable 9 cycle control valve that controls
backwash, slow/fast rinse, draw, refill, 2nd backwash and service up
to 9 cycles.
Progressive flow, parallel flow, alternating on demand soft water. System
designs up to 4 vessels.
Cycles of operation. Cycle One backwash 1-95 minutes or off, Cycle Two
brine draw 1 - 180 minutes or off, Cycle Three slow rinse 1 -
95 minutes or off, Cycle Four fast rinse 1 - 95 minutes or off, Cycle
Five refill 0.1 - 99 minutes or off, Cycle Six hold (service)
1 - 480 minutes or off, three additional cycles for backwash, slow rinse,
fast rinse.
Four methods to initiate regeneration, meter immediate, meter delayed,
time clock delayed or pressure differential.
2” water distribution system utilizing hub and laterals for maximum
flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F
- 110°F (5°C - 44°C).
Solid state microprocessor c/w removable front panel, digital display
for time of day, days until next regeneration, volume remaining, current
flow rate and total volume used (totalizer). All 9 cycles are adjustable
in second level diagnostics for desired flow rates in each cycle.
Double backwash for optimum regeneration cleaning ability and salt efficiency.
24volt output AC transformer, 12 or 24 hour time clock.
1 – 28 day override on control valve programming.
Brine tank salt grid for easy cleaning.
Brine tanks 30” x 50” or 50" x 60" c/w brine well and safety
float to eliminate overflowing tanks.
The brine tank has 1000lb or 4500lb water softening salt capacity.
2” inlet and outlet motorized bypass valve.
Series
EWS 3” Triplex Commercial Softener
FEATURES:
3” electronic microprocessor brass top mount control valve single or
multi unit systems with interlocking control valves.
Solid state electronic control processor c/w current flow rate, peak
flow rate, totalizer, hours between last two regenerations, hours since
last regeneration, volume remaining, remote start, time of day, cycle
step times and flow meter size, remote lockout variable reserve.
Fully adjustable 5 cycle control valve with backwash, brining, slow
rinse, rapid rinse, and service.
Service flow rates up to 250 USGPM, peak flow rate up to 325 USGPM,
backwash flow rate up to 100 USGPM.
Operating pressure
20-125 psi / 138-861 kpa, operating temperature 40°F - 110°F (5°C -
44°C).
Nema 3R water resistant enclosure, no hard water by-pass.
Meter accuracy plus or minus 5%, salt grind for easy cleaning.
Safety float
to eliminate brine tank from overflowing.
Drain line 2” NPT, Brine line 1" NPT, 3" Hub and Laterals.
Series
EWS 2” H Quadplex Commercial Softener
FEATURES:
2” NPT inlet or outlet/ 2 1/2" Victaulic lead free brass epoxy
coated control valve.
Electronic flow meters for each control valve with accuracy within plus
or minus 5 percent, flow rate range 1.5 to 125 gpm. Gallons range 10
to 999,000 gallons, 1000 to 999,999,000, gallons totalizer.
Service flow rate up to 125gpm, peak flow rate up to 150 gpm, backwash
flow rates up to 125 gpm.
Fully programmable and adjustable 9 cycle control valve that controls
backwash, slow/fast rinse, draw, refill, 2nd backwash and service, up
to 9 cycles.
Progressive flow, parallel flow, alternating on demand soft water.
System designs up to 4 vessels.
Cycles of operation. Cycle
One backwash 1 - 95 minutes or off, Cycle Two brine draw 1 - 180 minutes
or off, Cycle Three slow rinse 1- 95 minutes or off, Cycle Four fast
rinse 1 - 95 minutes or off, Cycle Five refill 0.1 - 99 minutes or off,
Cycle Six hold (service) 1 - 480 minutes or off, three additional cycles
for second backwash, slow rinse, fast rinse.
Four methods to initiate regeneration, meter immediate, meter delayed,
time clock delayed or pressure differential.
2” water distribution system utilizing hub and laterals for maximum
flow rates.
Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F
- 110°F (5°C - 44°C).
Solid state microprocessor c/w removable front panel, digital display
for time of day, days until next regeneration, volume remaining, current
flow rate and total volume used (totalizer).
Double backwash for optimum regeneration cleaning ability and salt efficiency.
24 volt output AC transformer, 12 or 24 hour time clock.
1 – 28 day override on control valve programming.
Brine tank salt grid for easy cleaning.
Brine tanks 30” x 50” or 50" x 60" c./w brine well and safety
float to eliminate overflowing tanks.
The brine tank has 1000lb or 4500lb water softening salt capacity.
2" inlet and outlet motorized bypass valve.
Series
EWS 3” Quadplex Commercial Softener
FEATURES:
3” electronic microprocessor brass top mount control valve single or
multi unit systems with interlocking control valves.
Solid state electronic control processor c/w current flow rate, peak
flow rate, totalizer, hours between last two regenerations, hours since
last regeneration, volume remaining, remote start, time of day, cycle
step times and flow meter size, remote lockout variable reserve.
Fully adjustable 5 cycle control valve with backwash, brining, slow
rinse, rapid rinse, and service.
Service flow rates up to 250 USGPM, peak flow rate up to 325 USGPM,
backwash flow rate up to 100 USGPM.
Operating pressure
20-125 psi / 138-861 kpa, operating temperature 40°F - 110°F (5°C -
44°C).
Nema 3R water resistant enclosure, no hard water by-pass.
Meter accuracy plus or minus 5%, salt grind for easy cleaning.
Safety float
to eliminate brine tank from overflowing.
Drain line 2” NPT, Brine line 1" NPT, 3" Hub and Laterals.
Please Contact Us to purchase any of these items or for a quote on any specialized commercial water softener application.